Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
World Neurosurg ; 2023 May 22.
Artigo em Inglês | MEDLINE | ID: covidwho-2325861

RESUMO

OBJECTIVE: Spine awake surgery (SAS) aims to achieve faster recovery times, better outcomes, and a lesser economic impact on society. Our drive to establish SAS was to improve patient outcomes and health economics during the COVID-19 pandemic. After a systematic review and to the best of our knowledge, SAS, the Oxford Protocol, is the first protocolized pathway that aims to train bespoke teams performing SAS safely, efficiently, and in a standardized repeatable fashion. A pilot study was designed around newly derived protocols and simulated training to determine if SAS is a safe and implementable pathway to improve patient outcomes and health economics. METHODS: We assessed a cohort of 10 patients undergoing one-level lumbar discectomies and decompressions, analyzing the related costs, length of stay, complications, pain management, and patient satisfaction. RESULTS: The age range of our patients was 46-84 years. Three discectomies and 7 central canal stenosis decompressions were performed. Eight patients were discharged on the same day. All patients gave positive feedback about their experience of SAS. A significant cost saving was made compared to a general anesthesia (GA) overnight stay across the group. No on day cancellations occurred due to lack of bed availability. No patient needed analgesia in the recovery room or needed additional analgesia over and above the SAS e-prescription take home package. CONCLUSIONS: Our early experience and journey reinforce our drive to push forward and expand on this process. It aligns with the international literature which highlights this approach as safe, efficient, and economical.

2.
Mol Genet Genomics ; 298(4): 955-963, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: covidwho-2326244

RESUMO

The study aimed to measure plasma levels of Mannose-Binding Lectin (MBL) and MBL-associated serine protease-2 (MASP-2) and their polymorphisms in COVID-19 patients and controls to detect association. As MBL is a protein of immunological importance, it may contribute to the first-line host defence against SARS-CoV-2. MBL initiates the lectin pathway of complement activation with help of MASP-1 and MASP-2. Hence, appropriate serum levels of MBL and MASPs are crucial in getting protection from the disease. The polymorphisms of MBL and MASP genes affect their plasma levels, impacting their protective function and thus may manifest susceptibility, extreme variability in the clinical symptoms and progression of COVID-19 disease. The present study was conducted to find plasma levels and genetic variations in MBL and MASP-2 in COVID-19 patients and controls using PCR-RFLP and ELISA, respectively.The present study was conducted to find plasma levels and genetic variations in MBL and MASP-2 in COVID-19 patients and controls using PCR-RFLP and ELISA, respectively. Our results indicate that median serum levels of MBL and MASP-2 were significantly low in diseased cases but attained normal levels on recovery. Only genotype DD was found to be associated with COVID-19 cases in the urban population of Patna city.


Assuntos
COVID-19 , Serina Proteases Associadas a Proteína de Ligação a Manose , Humanos , Serina Proteases Associadas a Proteína de Ligação a Manose/genética , Serina Proteases Associadas a Proteína de Ligação a Manose/metabolismo , População Urbana , COVID-19/epidemiologia , COVID-19/genética , SARS-CoV-2/genética , Genótipo
3.
Indian J Clin Biochem ; : 1-8, 2022 Jun 20.
Artigo em Inglês | MEDLINE | ID: covidwho-2232168

RESUMO

Introduction: Detecting low viral load has been a challenge in this pandemic, which has led to its escalated transmission. Complement activation has been implicated in pathogenesis of Covid-19 infection. Thus, evaluation of complement activation in suspected Covid-19 infection may help to detect infection and limit false negative cases thus limiting transmission of infection. We speculate that measuring C4b, produced from an activated complement system due to the presence of Covid-19 may help in its detection, even when the viral titers are low. Methods: Plasma C4b levels of symptomatic RT-PCR positive patients (cases, n = 40); symptomatic RT-PCR negative patients (n = 35) and asymptomatic RT-PCR negative controls (n = 40) were evaluated. Plasma C5b-9, IL-6, D-dimer and C1-Inhibitor (C1-INH) were also measured in cases and controls. ELISA kits were used for all measurements. Statistical analyses were carried out using Stata, version 12 (Stata Corp., Texas, USA). Results: C4b levels were found to be significantly increased in RT-PCR positive patients as compared to asymptomatic RT-PCR negative controls. RT-PCR negative but symptomatic patients still showed increased C4b levels. The significantly higher levels of C4b in cases with a cut-off value of ≥ 116 ng/ml with optimum sensitivity and specificity of 80% and 52% respectively is indicative of its possible use as an adjunct marker. Increased levels of D-dimer, IL6, along with decreased levels of C1-INH were found in cases compared to controls. Whereas, C5b-9 levels were not significantly raised in cases. Conclusions: The results of our study suggests that plasma C4b may help to detect infection in false negative cases of RT-PCR that escape detection owing to low viral load. However, to confirm it a large-scale study is needed. Supplementary Information: The online version contains supplementary material available at 10.1007/s12291-022-01033-z.

4.
Microsyst Nanoeng ; 8: 82, 2022.
Artigo em Inglês | MEDLINE | ID: covidwho-1937413

RESUMO

Effective containment of the COVID-19 pandemic requires rapid and accurate detection of the pathogen. Polymerase chain reaction (PCR) remains the gold standard for COVID-19 confirmation. In this article, we report the performance of a cost-effective modular microfluidic reverse transcription (RT)-PCR and RT-loop mediated isothermal amplification (RT-LAMP) platform, Epidax®, for the point-of-care testing and confirmation of SARS-CoV-2. This platform is versatile and can be reconfigured either for screening using endpoint RT-PCR or RT-LAMP tests or for confirmatory tests using real-time RT-PCR. Epidax® is highly sensitive and detects as little as 1 RNA copy per µL for real-time and endpoint RT-PCR, while using only half of the reagents. We achieved comparable results with those of a commercial platform when detecting SARS-CoV-2 viruses from 81 clinical RNA extracts. Epidax® can also detect SARS-CoV-2 from 44 nasopharyngeal samples without RNA extraction by using a direct RT-PCR assay, which shortens the sample-to-answer time to an hour with minimal user steps. Furthermore, we validated the technology using an RT-LAMP assay on 54 clinical RNA extracts. Overall, our platform provides a sensitive, cost-effective, and accurate diagnostic solution for low-resource settings.

5.
Indian journal of clinical biochemistry : IJCB ; : 1-8, 2022.
Artigo em Inglês | EuropePMC | ID: covidwho-1897936

RESUMO

Introduction Detecting low viral load has been a challenge in this pandemic, which has led to its escalated transmission. Complement activation has been implicated in pathogenesis of Covid-19 infection. Thus, evaluation of complement activation in suspected Covid-19 infection may help to detect infection and limit false negative cases thus limiting transmission of infection. We speculate that measuring C4b, produced from an activated complement system due to the presence of Covid-19 may help in its detection, even when the viral titers are low. Methods Plasma C4b levels of symptomatic RT-PCR positive patients (cases, n = 40);symptomatic RT-PCR negative patients (n = 35) and asymptomatic RT-PCR negative controls (n = 40) were evaluated. Plasma C5b-9, IL-6, D-dimer and C1-Inhibitor (C1-INH) were also measured in cases and controls. ELISA kits were used for all measurements. Statistical analyses were carried out using Stata, version 12 (Stata Corp., Texas, USA). Results C4b levels were found to be significantly increased in RT-PCR positive patients as compared to asymptomatic RT-PCR negative controls. RT-PCR negative but symptomatic patients still showed increased C4b levels. The significantly higher levels of C4b in cases with a cut-off value of ≥ 116 ng/ml with optimum sensitivity and specificity of 80% and 52% respectively is indicative of its possible use as an adjunct marker. Increased levels of D-dimer, IL6, along with decreased levels of C1-INH were found in cases compared to controls. Whereas, C5b-9 levels were not significantly raised in cases. Conclusions The results of our study suggests that plasma C4b may help to detect infection in false negative cases of RT-PCR that escape detection owing to low viral load. However, to confirm it a large-scale study is needed. Supplementary Information The online version contains supplementary material available at 10.1007/s12291-022-01033-z.

6.
PLoS Negl Trop Dis ; 15(8): e0009101, 2021 08.
Artigo em Inglês | MEDLINE | ID: covidwho-1416858

RESUMO

BACKGROUND: In 2005, Bangladesh, India and Nepal agreed to eliminate visceral leishmaniasis (VL) as a public health problem. The approach to this was through improved case detection and treatment, and controlling transmission by the sand fly vector Phlebotomus argentipes, with indoor residual spraying (IRS) of insecticide. Initially, India applied DDT with stirrup pumps for IRS, however, this did not reduce transmission. After 2015 onwards, the pyrethroid alpha-cypermethrin was applied with compression pumps, and entomological surveillance was initiated in 2016. METHODS: Eight sentinel sites were established in the Indian states of Bihar, Jharkhand and West Bengal. IRS coverage was monitored by household survey, quality of insecticide application was measured by HPLC, presence and abundance of the VL vector was monitored by CDC light traps, insecticide resistance was measured with WHO diagnostic assays and case incidence was determined from the VL case register KAMIS. RESULTS: Complete treatment of houses with IRS increased across all sites from 57% in 2016 to 70% of houses in 2019, rising to >80% if partial house IRS coverage is included (except West Bengal). The quality of insecticide application has improved compared to previous studies, average doses of insecticide on filters papers ranged from 1.52 times the target dose of 25mg/m2 alpha-cypermethrin in 2019 to 1.67 times in 2018. Resistance to DDT has continued to increase, but the vector was not resistant to carbamates, organophosphates or pyrethroids. The annual and seasonal abundance of P. argentipes declined between 2016 to 2019 with an overall infection rate of 0.03%. This was associated with a decline in VL incidence for the blocks represented by the sentinel sites from 1.16 per 10,000 population in 2016 to 0.51 per 10,000 in 2019. CONCLUSION: Through effective case detection and management reducing the infection reservoirs for P. argentipes in the human population combined with IRS keeping P. argentipes abundance and infectivity low has reduced VL transmission. This combination of effective case management and vector control has now brought India within reach of the VL elimination targets.


Assuntos
Controle de Insetos/normas , Insetos Vetores/parasitologia , Inseticidas/administração & dosagem , Leishmaniose Visceral/prevenção & controle , Phlebotomus/parasitologia , Animais , Bioensaio , Feminino , Humanos , Índia/epidemiologia , Controle de Insetos/métodos , Resistência a Inseticidas , Leishmaniose Visceral/epidemiologia , Psychodidae/efeitos dos fármacos , Piretrinas/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA